First Flush Delta Commercial

A high volume first flush diverter, perfect for commercial applications. All fittings are included to install the unit in systems with large pipe diameters.

Just supply 100mm or 4" pipe to make the chamber and you can start diverting larger volumes of water.

Divert Large volumes of water, easily

Divert Large volumes of water, easily

Easily divert large volumes of water with Delta's unique manifold design which only requires you to use smaller diameter pipe.
Ultimate First Flush control

Ultimate First Flush control

By setting the regularity of your first flush diversion, you can optimise how often your First Flush Diverter drains.
Just add pipe

Just add pipe

The First Flush Delta Commercial comes with all fittings you need to set the system up. Just add the pipe to create the storage chamber.
Easy Maintenance

Easy Maintenance

The large opening on the valve reduces the chance of clogging when compared to a traditional slow release valve.
SKU :
#002f6c
White
0
0
0
0
First Flush Delta Commercial
ic

Benefits

Divert Large volumes of water, easily

Standard large format First Flush Diverters require you to use large diameter pipe (eg, 300mm / 12"). It can be difficult to source in smaller lengths and can be expensive.

The Delta's unique manifold design uses lengths of 100mm or 4" pipe instead, so sourcing the pipe to make the chamber is easier. It means you can assemble your First Flush Diverter quicker, to get the job done.

Each 1 meter of length in the Delta = 73 L diversion.
Each 1 yard of length in the Delta = 17.5 gal diversion.

Benefits

Ultimate First Flush control

By setting the regularity of your first flush diversion, you can optimise how often your First Flush Diverter drains.

Do you want the best quality water possible? Set it to a regular reset interval of three days or less.

Do you need to maximise the volume of water your capture? Increase the reset interval to two weeks or more.

Want to start off with a great compromise of water quality and quantity? Try five days.

Benefits

Less maintenance and clogging

Traditional First Flush Diverter valves have a tendency to clog over time - they only have a tiny hole so it is inevitable. The release valve on the Delta First Flush includes a unique funnel design and a much larger draining hole, which means that water drains as it's supposed to and there is far less chance of the unit becoming clogged.

Benefits

Just add pipe

The First Flush Delta Commercial comes with all fittings you need to set the system up. Just add the pipe to create the storage chamber.

There are different kits available with different sized T-pieces and reducers, so choose the one for your needs. You can even buy the kit without them if it's more practical.

Benefits

Divert Large volumes of water, easily

Standard large format First Flush Diverters require you to use large diameter pipe (eg, 300mm / 12"). It can be difficult to source in smaller lengths and can be expensive.

The Delta's unique manifold design uses lengths of 100mm or 4" pipe instead, so sourcing the pipe to make the chamber is easier. It means you can assemble your First Flush Diverter quicker, to get the job done.

Each 1 meter of length in the Delta = 73 L diversion.
Each 1 yard of length in the Delta = 17.5 gal diversion.

Benefits

Ultimate First Flush control

By setting the regularity of your first flush diversion, you can optimise how often your First Flush Diverter drains.

Do you want the best quality water possible? Set it to a regular reset interval of three days or less.

Do you need to maximise the volume of water your capture? Increase the reset interval to two weeks or more.

Want to start off with a great compromise of water quality and quantity? Try five days.

Benefits

Less maintenance and clogging

Traditional First Flush Diverter valves have a tendency to clog over time - they only have a tiny hole so it is inevitable. The release valve on the Delta First Flush includes a unique funnel design and a much larger draining hole, which means that water drains as it's supposed to and there is far less chance of the unit becoming clogged.

Benefits

Just add pipe

The First Flush Delta Commercial comes with all fittings you need to set the system up. Just add the pipe to create the storage chamber.

There are different kits available with different sized T-pieces and reducers, so choose the one for your needs. You can even buy the kit without them if it's more practical.

Product Installation, Maintenance and Information

Yes
Yes
Yes

Specifications

All measurements are in mm unless specified otherwise

Click the drawing to view it in full size

Pipe Fitment

You may also like

We’re sorry, the product you are looking for is not available in this region. Click here to view all available products for this region.

If you need help, please contact our team who will be glad to assist.

Looking for something else?

View the full product range from our home base in Australia.

First Flush Calculator by Rain Harvesting

First Flush Calculator

Easily calculate how much water you need to divert and discover which First Flush Diverter is right for you.

Design Service

Improve your existing Rain Harvesting system or design a new one with the help of our experts and our free system design service.

Free Handbooks by Rain Harvesting

Rain Harvesting Handbook

A guide that will provide you with help and inspiration to start your rainwater harvesting journey today.

A sketch of mechanics about rain harvesting

Design Service

Improve your existing Rain Harvesting system or design a new one with the help of our experts and our free system design service.